This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
840 Series
Control valves for general applications
The 840 series cage-guided valve is specially designed using recent advances in control valve technology. It is used to control a wide variety of relatively clean liquids and gases at high pressure differentials. Configured with either flow-to-open or flow to- close trims, the valve is well suited for steam, gas or liquids, where flow-to-close is typically used for liquid service, and flow-to open for steam and gas. The design of the 840H (drilled-hole-cage)valve is primarily used for severe service applications requiring anti-cavitation or low-noise trim. In most cases, high pressure drop in process conditions may cause erosion, noise or vibration, which can affect process control. The 840H is a good solution to this severe service application.
The 840 series valve is flexible, allowing a variety of trim types to be installed in the body. In addition, its cage-guided construction reduces plug vibration and provides stable performance throughout travel. All 840 trims have a quick change design to guarantee convenient repair and easy trim replacement.
- Multi-spring- Multi-spring design allows very low hysteresis and dead band.
- Proven trim design – Single P-port, multi-step, V-notch type cage.
- Fail mode – Fail-to-close on loss of air is standard. – Fail-to-open on loss of air is also available. – Diaphragm, piston, hydraulic and electric actuation available.
- Quick change trim – All internal parts can be inspected easily by removing bonnet and cage.
- Accessories – A full range are available to meet requirements.

Product Specifications

Valve size
- 1” through 20”
Ratings
- ANSI class 150-2500 (DIN and JIS available)
End connections
- Raised face flange, weld ends (BW and SW)
Flow characterisation
- Linear on equal percentage to suit application
Seat leakage
- Standard ANSI class IV, option-ANSI class V or VI
Temperature range (general)
- 1/2”~4”: -30ºC ~ 300ºC (Standard), -196ºC ~ 565ºC (Ext.)
- 6”~20”: -30ºC ~ 300ºC (Standard), -196ºC ~ 565ºC (Ext.)